CV2430 S-band pre-TR Cell
Size This TR cell measures 130mm long by 25mm at the widest point (16mm across the main body).

This is a plug-in type cell designed to work in a waveguide.

Operating frequency range S-band
Max peak power 500kW
Min peak power 10kW
Max mean power 500W
Typical operating conditions
Centre frequency 3305MHz
Loaded Q 1.0
Insertion loss 0.07dB
Recovery time 4.0µs
Arc loss 0.4dB at 10kW power
Position of short circuit 0.09 inches
CV2430
Top quarter view Bottom quarter view
Tin Packaging