Virtual Valve Museum

Virtual Valve Museum

HomeFull List

This is an archive website. It will not receive any updates, additions or corrections.

CV293 TR Cell

CV293 size The cell measures 125x30mm (glass section) and 113x63mm across the flange. It weighs 400g.

The serial number Z12102 is marked around the connector, and the number 230129 appears on the rear face of the flange.

CV293

This is a version of CV193 modified for waveguide output. See also CV497 which is a modified version of this TR Cell.

Operating frequency 2925 to 3075MHz
Min primer supply voltage -800V
Primer operating current 100 to 150µA
Max peak power 500kW

 

CV293 flange
CV293 insideCV293 inside
CV293 stub
CV293 box CV293 in box