CV4051 reliable DC stable
double triode
 |
This valve measures 51x19mm
overall and has a B9A/F base |
This valve was specifically
intended for DC amplifier operation in a cathode coupled circuit.
| Heater voltage |
6.3V/12.6V |
| Heater current |
600mA/300mA |
| Max anode voltage |
300V |
| Max anode dissipation |
1W |
| Anode current * |
1.5mA |
| Mutual conductance * |
1.3mA/V |
| Amplification factor * |
31 |
| Max bulb temperature |
120C |
| Max altitude |
60,000 feet |
| Max acceleration (continuous
operation) |
2.5g |
| Max shock |
500g |
| Capacitances |
| Ca', a" |
0.46pF |
| Ca, g |
1.9pF |
| C in |
2.2pF |
| C out |
2.5pF |
* : At Va=150, Vg=-3.75.
| Lead |
Function |
| 1 |
Anode " |
| 2 |
Grid " |
| 3 |
Cathode " |
| 4 |
Heater |
| 5 |
Heater |
| 6 |
Anode ' |
| 7 |
Grid ' |
| 8 |
Cathode ' |
| 9 |
Heater centre tap |
|
 |