Virtual Valve Museum

Virtual Valve Museum

HomeFull List

This is an archive website. It will not receive any updates, additions or corrections.

CV6028 pre-TR cell

Size
This valve measures 195x11mm overall (8mm across the glass)

This is a broadband, low loss, plug-in pre-TR cell.

Frequency range2 to 12GHz
Max breakdown power20kW
Max recovery period to -3db25µs
Max peak transmitter power2.5MW
Max mean transmitter power3kW
Max pulse length2.5µs
Max waveguide pressure300kN/m2
Ambient temperature range-50 to +100°C

CV6028